  d a t a sh eet supersedes data of september 2004 2008 sep 01 ferroxcube e32/6/20/r planar e cores and accessories
2008 sep 01 2 ferroxcube planar e cores and accessories e32/6/20/r cores effective core parameters of an e/plt combination ordering information for plates symbol parameter value unit (i/a) core factor (c1) 0.278 mm ? 1 v e effective volume 4560 mm 3 i e effective length 35.1 mm a e effective area 130 mm 2 a min minimum area 119 mm 2 m mass of core half 13 g m mass of plate 10 g grade type number 3c90 plt32/20/3.2/r-3c90 3c92 plt32/20/3.2/r-3c92 3c93 plt32/20/3.2/r-3c93 3c94 plt32/20/3.2/r-3c94 3c95 plt32/20/3.2/r-3c95 3c96 plt32/20/3.2/r-3c96 3f3 plt32/20/3.2/r-3f3 3f4 plt32/20/3.2/r-3f4 mfp055 31.75 0.64 24.9 min. 3.18 0.2 20.32 0.41 r0.64 ref. typ. r0.25 typ. 6.35 0.13 6.35 0.13 5.3 5 + 0.2 0 fig.1 e32/6/20/r. dimensions in mm. mfp056 31.75 0.64 20.32 0.41 3.18 0.13 r0.64 ref. typ. 5 + 0.2 0 2.13 fig.2 plt32/20/3.2/r. dimensions in mm.
2008 sep 01 3 ferroxcube planar e cores and accessories e32/6/20/r core halves for use in combination with a recessed plate (plt/r) a l measured in combination with a recessed plate (plt/r), clamping force for a l measurements, 30 10 n. grade a l (nh) e air gap ( m) type number 3c90 160 3% 35 1200 e32/6/20/r-3c90-a160-p 250 3% 55 700 e32/6/20/r-3c90-a250-p 315 3% 69 550 e32/6/20/r-3c90-a315-p 400 5% 87 450 e32/6/20/r-3c90-a400-p 630 8% 138 260 e32/6/20/r-3c90-a630-p 7350 25% 1610 0 e32/6/20/r-3c90 3c92 5760 25% 1270 0 e32/6/20/r-3c92 3c93 6780 25% 1500 0 e32/6/20/r-3c93 3c94 160 3% 35 1200 e32/6/20/r-3c94-a160-p 250 3% 55 700 e32/6/20/r-3c94-a250-p 315 3% 69 550 e32/6/20/r-3c94-a315-p 400 5% 87 450 e32/6/20/r-3c94-a400-p 630 8% 138 260 e32/6/20/r-3c94-a630-p 7350 25% 1610 0 e32/6/20/r-3c94 3c95 8750 25% 1880 0 e32/6/20/r-3c95 3c96 7350 25% 1610 0 e32/6/20/r-3c96 3f3 160 3% 35 1200 e32/6/20/r-3f3-a160-p 250 3% 55 700 e32/6/20/r-3f3-a250-p 315 3% 69 550 e32/6/20/r-3f3-a315-p 400 5% 87 450 e32/6/20/r-3f3-a400-p 630 8% 138 260 e32/6/20/r-3f3-a630-p 6780 25% 1490 0 e32/6/20/r-3f3 3f4 160 3% 35 1200 e32/6/20/r-3f4-a160-p 250 3% 55 700 e32/6/20/r-3f4-a250-p 315 3% 69 550 e32/6/20/r-3f4-a315-p 400 5% 87 450 e32/6/20/r-3f4-a400-p 630 8% 138 260 e32/6/20/r-3f4-a630-p 3700 25% 810 0 e32/6/20/r-3f4
2008 sep 01 4 ferroxcube planar e cores and accessories e32/6/20/r properties of core sets under power conditions properties of core sets unde r power conditions (continued) grade b (mt) at core loss (w) at h = 250 a/m; f = 10 khz; t=100 c f = 100 khz; =100mt; t = 100 c f = 100 khz; = 200 mt; t=25 c f=100khz; = 200 mt; t=100 c f = 400 khz; =50mt; t=100 c e32/r+plt32/r-3c90 320 0.55 ??? e32/r+plt32/r-3c92 370 0.41 ? 2.9 ? e32/r+plt32/r-3c93 320 0.41 (1) 1. measured at 140 c. ? 2.9 (1) ? e32/r+plt32/r-3c94 320 0.41 ? 2.9 ? e32/r+plt32/r-3c95 320 ? 2.69 2.55 ? e32/r+plt32/r-3c96 320 0.3 ? 2.2 0.8 e32/r+plt32/r-3f3 300 0.6 ?? 0.85 e32/r+plt32/r-3f4 250 ???? grade b (mt) at core loss (w) at h = 250 a/m; f = 10 khz; t=100 c f=500khz; =50mt; t=100 c f = 500 khz; = 100 mt; t=100 c f=1mhz; =30mt; t = 100 c f=3mhz; =10mt; t = 100 c e32/r+plt32/r-3c90 320 ???? e32/r+plt32/r-3c92 370 ???? e32/r+plt32/r-3c93 320 ???? e32/r+plt32/r-3c94 320 ???? e32/r+plt32/r-3c95 320 ???? e32/r+plt32/r-3c96 320 1.7 ??? e32/r+plt32/r-3f3 300 ???? e32/r+plt32/r-3f4 250 ?? 1.36 2.2 b ? b ? b ? b ? b ? b ? b ? b ?
2008 sep 01 5 ferroxcube planar e cores and accessories e32/6/20/r data sheet status definitions disclaimer life support applications ? these products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify ferroxcube for any damages resulting from such application. product status definitions data sheet status product status definitions preliminary specification development this data sheet contains prelimin ary data. ferroxcube reserves the right to make changes at any time without not ice in order to improve design and supply the best possible product. product specification production this data sheet contains final specifications. ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. status indication definition prototype these are products that have been made as development samples for the purposes of technical evaluation only. the data for these types is provisional and is subject to change. design-in these products are recommended for new designs. preferred these products are recommended for use in current designs and are available via our sales channels. support these products are not recommended for new designs and may not be available through all of our sales channels. customers are advised to check for availability.